Low breakdown (75–600 V)
Signal common-mode & ports, < 1 pF.
Mid/high (600–2500 V)
First power stage, 8/20 withstand 2–50 kA.
3-electrode
Center electrode for three-phase common-mode.
High IPP
Withstands 100 kA for 5G & power-line.
Gas discharge tubes offer nominal DC breakdown 75 V–10000 V in 2- or 3-electrode construction, 8/20 surge withstand 2 kA–100 kA, with < 1 pF interelectrode capacitance. They serve common-mode signal protection and the first high-current stage of power lines.
| Dimension | Typical range | Note |
|---|---|---|
| Breakdown | 75–10000 V | by signal/power |
| Surge rating | 2–100 kA (8/20) | 3-electrode higher |
| Interelectrode C | < 1 pF | good for high speed |
| Structure | 2 / 3 electrode | 3-electrode has center |
| Failure mode | short | needs downstream stage |
Gas discharge tubes offer nominal DC breakdown 75 V–10000 V in 2- or 3-electrode construction, 8/20 surge withstand 2 kA–100 kA, with < 1 pF interelectrode capacitance. They serve common-mode signal protection and the first high-current stage of power lines.
| Dimension | Typical range | Note |
|---|---|---|
| Breakdown | 75–10000 V | by signal/power |
| Surge rating | 2–100 kA (8/20) | 3-electrode higher |
| Interelectrode C | < 1 pF | good for high speed |
| Structure | 2 / 3 electrode | 3-electrode has center |
| Failure mode | short | needs downstream stage |