TMOV — Thermally Protected Varistor
A varistor with an integrated thermal disconnector and fault indicator, resolving the fire risk of thermal runaway in ordinary MOVs.
Overview
A TMOV (Thermally Protected Varistor) packages a MOV die together with a thermal disconnector bonded to the chip and a fault-indicator lead. Its sole reason to exist is to remove the most dangerous failure mode of a plain MOV—thermal runaway and fire.
Principle
The thermal disconnector senses the MOV chip temperature. When the MOV overheats from aging, sustained overvoltage or repeated surges, the disconnector mechanically and permanently opens the internal connection, putting the device into a high-impedance/open state and signaling failure via the indicator lead (open or short, depending on type).
This breaks the "MOV shorts → continuous heating → ignites surroundings" accident chain.
Key Parameters
Beyond the MOV parameters (Vn, Vc, Ip, W, C), note:
| Parameter | Meaning |
|---|---|
| disconnect temperature | chip temperature that triggers opening |
| fault output | indicator state after opening (NO/NC type) |
| max continuous operating voltage | the Uc equivalent |
Selection Checklist
- Prefer TMOV for any mains-connected MOV: adapters, LED drivers, appliance boards.
- Confirm disconnect temperature and package compatibility; TMOV is usually slightly larger than an equivalent MOV.
- Use the fault indicator in system alarm or forced-shutdown logic for "fail-visible" design.
- Still obey MOV Vn/Vc/energy rules.
Typical Applications
AC adapters, LED drivers, appliance control boards, industrial power supplies, any unattended mains equipment a person can touch.
Coordination with Neighboring Devices
- TMOV is the safe upgrade of MOV; voltage/energy parameters map almost directly when replacing a bare MOV.
- Still pair with a GDT in lightning-heavy areas to reduce TMOV energy burden.
- Upstream SCPD is still required for the pre-disconnect short-circuit case.
Failure Modes and Life
A properly aging TMOV disconnects before fire, shown by a flipped indicator and open impedance—this is safe failure, not dangerous failure.
Standards
- IEC 62368-1: requires thermal protection (or overall over-temperature protection) for mains-connected MOVs; TMOV is the mainstream compliant solution.
- Element level still follows IEC 61051 / IEC 61643-11.
Tip
Upgrading a bare MOV to TMOV is nearly a "no-re-qualification" lowest-risk change—align voltage/energy and you close the fire-safety gap.
Next
- Read MOV
- Read Overvoltage selection & coordination